Description
WIREX installation cables are characterized by high reliability and stability of parameters throughout the lifetime of the installed metallic data network. They can handle the most demanding transmission protocols that can be operated on CAT6 cabling according to standards. This type of cable can be installed in outdoor environments, where the quality sheath withstands both temperature conditions and sunlight. The cable is supplied in a coloured box, which makes it possible to quickly identify which type of cable it is in the case of installations where several types of cable are used. For clarity, the cable metreage is marked from 0 m to 500 m.
Cable construction
Element | Description | Values |
Driver | Copper wire AWG23 0.57 ± 0.01 mm |
Isolation | HDPE 1.1 ± 0.08 mm |
Protective tape | PET 0.02 mm |
Shading | Aluminium foil 0.06 mm |
Earthing conductor | Tinned copper 0.4 mm |
Sheath thickness | 0.5 mm |
Cable diameter | 7.6 ± 0.5 mm |
Sheath colour | 9005 black |
Technical data
Parameters | Description | Values |
Bandwidth | 250 MHz |
Supported protocols | 1000BaseT, 1000BaseTX |
Supported PoE standards | PoE, PoE |
Supported standards | ANSI/TIA 568, ISO/IEC 11801, EN 50173 |
Numbering of metrage | 0-500 m |
Categories | CAT6 |
Variant of shading | F/UTP |
Cloak | PE |
Mechanical properties
Parameters | Description | Values |
Tensile resistance | 80 N max. |
Bending radius | 50 mm |
Cable weight | 52 kg/km |
Packaging | Coil 500 m |
Installation temperature | 0 to 75 °C |
Operating temperature | -20 to 75 °C |
Electrical properties
Parameters | Description | Values |
Driver impedance | Max. 9.5 Ω/100 m |
Driver impedance deviation | Max. 2.5 % |
Insulation resistance | Min. 5000 MΩ*km (at DC 500 V/1 min) |
Dielectric Resistance | 1 kV (at DC 1 min, core-to-core) |
Capacity | Max. 5.6 nF/100 m |
Signal delay difference | Max. 45 ns/100 m (at 1 MHz - 100 MHz) |
NRC | 69 % |